GPIs OUT - Function

Description

Specifies the function that activates the output line.

Values

The following functions can be triggered by a GPI OUT:

Replace

GPIs OUT - Type

Description

Specifies the type of GPI output signal that will trigger the
specified function.

Values

The following values are possible:

close

The level changes to high level at
activation.

close
pulse

A rising edge pulse is generated at
activation.

open

The level changes to low level at
activation.

open
pulse

A falling edge pulse is generated at
activation.

GPIs OUT - Advance

Description

Defines the time (number of seconds and/or frames), at which
the output will be generated ahead of the timecode linked to the
output line.

Values

00s00fr to 02s00fr

Disable

Default value

Disable

GPIs OUT - Pulse duration

Description

Defines the pulse duration (number of seconds and/or frames)
for pulse type output lines.

Values

00s00fr to 02s00fr (2fr steps)

Disable

Default value

Disable