PROGRAMMABLE FEATURES

The following explains the programmable features of the PN 6530 Ignition. These instructions serve

as an overview of the features and their operation. The Pro-Data+ software also has a Help Menu

that explains many features in great detail. The features are listed in the same order that they show

on the Data Editor list in the software.

Note: If you are programming the timing functions of the ignition, the distributor will require being

locked-out.

STATS

Stat 1: This is only used with the Hand Held Monitor, PN 7550.

REV LIMITS

Up to three different rev limits can be programmed in 100 rpm increments.

RevBurn: Burnout Rev Limit. This limit is activated when 12 volts are applied to the Light Blue

wire. It is adjustable from 2,000 to 12,500 rpm.

RevLaunch: Launch Rev Limit. This limit is activated when 12 volts are applied to the Dark Blue

wire. It is adjustable from 1,000 to 12,500 rpm.

RevMax: Max Speed Rev Limit. This is the over-rev limit and is active whenever the Launch and

Burnout limits are off.