Wiring – MSD 6530 Digital Programmable 6AL-2 Installation User Manual

Page 4

Advertising
background image

4

INSTALLATION INSTRUCTIONS

M S D  

•   W W W . M S D P E R F O R M A N C E . C O M   •   ( 9 1 5 )   8 5 7 - 5 2 0 0   •   F A X   ( 9 1 5 )   8 5 7 - 3 3 4 4

WIRING

Ignition supply wire, 14-gauge. Connects to battery positive (+) terminal or battery

junction.

Note: Do not connect to the alternator.

Ignition ground, 14-gauge. Connect to battery negative (-) terminal or engine block.

Primary Coil Leads (18-gauge)

Orange

Connects to the coil positive (+) terminal. This is the only wire that makes contact

to the coil positive terminal.

Black

Connects to the coil negative (-) terminal. This is the only wire that makes contact

to the coil negative terminal.

WARNING: High voltage is present at the coil primary terminals. Do not touch the coil or connect

test equipment to the terminals while the engine is running or cranking.

Trigger Wires(18-gauge)

Violet/

Magnetic pickup, 2-pin connector. Plugs into an MSD Distributor or Crank Trigger

pickup. Violet is positive, Green is negative.

When this connector is used, the White

and White/Blue wires are not connected.

White/

White

Trigger input for electronic ignition amplifiers, an ECU’s trigger or points.

When this wire is used, the magnetic pickup and White/Blue wires are not con-

nected.

Red

On/Off switch wiring. Connects to a switched 12 volt source.

Green

2-Pin

Blue

2-PIN

CONNECTOR

Heavy

Red

Heavy

Black

2-PIN

CONNECTOR

8-PIN

CONNECTOR

Hall-Effect or ECU trigger. This wire connects to the trigger wire of the Hall-Effect pickup.

It can also be connected to an ECU trigger source (low voltage and current). See page

6.

When used, the White and Magnetic Pickup wires are not connected.

Dark Blue

Launch Rev Limit. When 12 volts are applied to this wire it will activate the Launch Rev

Limit and reset the Launch Retard. This overrides other rev limits.

Light Blue

Burnout Rev Limit. When 12 volts are applied the Burnout Rev Limit is active.

Gray

Tach output. This wire provides a 12 volt, 20° signal that is compatible with most tachs

and data acquisition systems.

Pink

Retard Step. This retard is activated when 12 volts are applied and rpm is above the

Step1 Rpm value.

3-Pin Connector, MAP Sensor

Connects to an external MAP or gauge pressure sensor.
Brown/Violet +5 volt supply
Brown/Yellow Ground
Dark Brown Map Signal

Advertising