1 output generator interface – Soft dB Opus Suite Data Logger Module User Manual

Page 16

Advertising
background image

15

Click the Edit Output button for more details or to modify the generator.

6.4.1

Output Generator interface

The output generator is made of a multi-tone generator (up to five tones) and of a noise generator

(white noise and/or pink noise). Each part of the generator can be mixed to outputs 1 and 2.

Output Generator

Tone Frequency in Hertz.

This control sets the frequency of to tone to be generated.

Signal Level in percent of full amplitude.

The value of this level can be adjusted through the slide control or fine tuned

with the numeric control.

Pink Noise Cut-off Frequency in Hertz.

This controls set the frequency at which the power density of the pink noise

starts to fall (10 dB/decade). The default value is 100 Hz.

Output Mix

This control maps its part of the generator to the specified output.

Both parts of the generator can be summed to the same output, mapped to

different outputs or simply turned off.

Care should be taken to avoid output saturation. Each Level(%) can be adjusted to the full output

range (100%). When the signals are added at the output, there is a risk that the resulting signal

Advertising