Veris Technologies OpticMapper - Operating Instructions User Manual

Page 53

Advertising
background image

Pub.# OM17-OpticMapper

6-19

Procedure #7: Lubrication



• Pinch point hazard: to prevent injury, stand clear when raising or lowering any part of the Veris
MSP. Disengage automatic cycling function before working around unit.
• Install all transport locks before transporting or working underneath.


Rockshaft pivot points

– Each pivot (located at the left and right) contains

an upper and lower grease zerk. Due to the limited motion of the
rockshaft, these should be lubricated on 20-hour intervals. This may
vary based on the number of times the unit is raised and lowered.

Figure 7.1

Rachet jack --

20 hour intervals

Figure 7.2


Electrode coulters Pivot --In all but the most extremely rocky conditions, the coulter electrodes
should not flex in the field, thus minimal movement will be realized at the pivot. 80-hour
intervals should be sufficient.

Pivot grease
zerks (2 per

hangar; 4 total )

grease zerks

Advertising