Pressure transmitters D76 and D77

9

Product description

Long-term stability

Longterm drift of the zero signal

1)

- D76 (ceramic measuring cell)

< 0.1 %/year

- D77 (metallic measuring cell)

< 0.25 %/year

Other actuating variables

Calibration position

upright, diaphragm points downwards

Influence of the mounting location
- ceramic measuring cell

< 0.2 mbar

- metallic measuring cell

< 5.0 mbar

Vibration resistance

mechanical vibrations with 4 g and

5 … 100 Hz, tested acc. to the regulations of
German Lloyd, GL regulation 2

Operating conditions

Ambient conditions

Ambient temperature

-40°C … +60°C

Storage and transport temperature

-40°C … +60°C

Product temperature

-40°C … +60°C

Protective measures

Transmitter

IP 68

Housing

2)

IP 66 or IP 67, IP 68 (by fixed connected
PE-cable, cable length min. 5 m)

General data

Connection cables

Cable entry
- in connection housing

2 x M20 x 1.5 (for cable ø 5 … 9 mm)

- external housing VEGABOX 01

2 x M20 x 1.5 (for cable ø 5 … 9 mm)

Screw terminals
- terminal, adjustment insert

for conductor cross-sections up to 2.5 mm

2

- external connection housing

VEGABOX 01

for conductor cross-sections up to 2.5 mm

2

1)

Acc. to IEC 770, item 6.1.2 relating to the nominal measuring range.

2)

Use of suitable seal in the PG is necessary for maintaining the housing protection IP 65 or IP 67.

Advertising