VEGA VEGASWING 83A User Manual

Page 6

Advertising
background image

6

VEGASWING 81A and 83A

Product description

Overfill protection according to WHG

Level detection with fault monitoring

Instrument

Oscillator

VEGATOR

Test certificate no.

level switch

VEGASWING

SWING E82Z EX

536 EX,

Z-65.11-154

81A EX, 83A EX

537 EX

636 EX

VEGASWING

SWING E82 C

Compact instrument

Z-65.11-163

81A and 83A

SWING E82 R

(C, R, T)

SWING E82 T

Level measuring instruments for use in hazardous areas

Level detection with fault monitoring

Instrument

EU-type approval

VEGATOR

Conformity

certificate

level

certificate

switch

VEGASWING

TÜV 98 ATEX 1320 X

536 EX

PTB no. Ex 95.D.2065 X

81A EX, 83A EX

537 EX

PTB no. Ex 95.D.2073 X

with

636 EX

PTB no. Ex 96.D.2068

oscillator
SWING E82Z EX

Overfill protection

The information and conditions of the sup-
plied general type approvals must be noted
when a VEGASWING is used as part of an
overfill pr otection for vessels storing water -
endangered liquids. The general type ap-
proval should be available at the place of
installation place.
VEGASWING should only be used in liquids
against which the materials of the wetted
parts of VEGASWING are sufficiently chemi-
cally resistant.

VEGATOR 425 EX, 534 EX and 825 EX signal conditioning instruments meet the r equired
connection values and can also be used.

DruckbehV (pressure vessel regula-
tions)

VEGASWING was tested acc. to TRB 801 no.
45 on its suitability for use in pressurized
vessels (DruckbehV).