6 Instrument modification

6.1 Exchange of adjustment

modules

The modular construction of VEGABAR allows
retrofitting, interchange or removal of the
display module. Data previously saved (e.g.
adjustment values) are not stored in the ad-
justment module but in an EEPROM of the
electronics module and therefore
readjustment is not necessary. The
connection of the modules is made via a 4-
pole plug connection.

Exchange of the adjustment module

Removal of the adjustment module

Separate VEGABAR from the power
supply

Remove the screws on the upper side of
the housing and remove the cover or the
display module

Disconnect connection cables from the
terminals, and if applicable, pull out the
plug connection of the display module

Remove the two screws of the adjustment
module

Remove adjustment module and pull out
plug connection

Insertion of an adjustment module

Plug the plug connection of the new ad-
justment module into the plug-in socket of
the electronics module

Fasten the new adjustment module

Reconnect the connection cables, and if
applicable, also the cable from the
display module

Replace the cover or the display module
of VEGABAR

Reconnect VEGABAR to power supply

VEGABAR