Capacitive electrodes EL …

Oscillators in two-wire technology for capacitive electrodes EL

Type

Application

Meas. range Meas. frequency

Signal
conditioning
instrument

E14

Level detection in general

I: 0 … 25 pF

400 kHz

VEGATOR

II: 0 … 100 pF

VEGALOG

III: 0 … 400 pF

E15

Level detection in general

I: 0 … 25 pF

400 kHz

VEGATOR

with potential separation

II: 0 … 100 pF

VEGALOG

III: 0 … 400 pF

E15 Ex

like E15, however for the use in

I: 0 … 25 pF

400 kHz

VEGATOR Ex

hazardous areas according to

II: 0 … 100 pF

VEGALOG

1)

CENELEC, PTB zone 0 as well as

III: 0 … 400 pF

zone 0 and StEx zone 10 and as
part of an overfill protection acc. to
WHG (VbF)

E17

Continuous level measurement

I: 0 … 120 pF

40 kHz

VEGAMET

in general or level detection

II: 0 … 600 pF

VEGALOG

with potential separation

III: 0 … 3000 pF

(VEGATOR)

E17 Ex

like E17, however for the use in

I: 0 … 120 pF

40 kHz

VEGAMET Ex

hazardous areas according to

II: 0 … 600 pF

VEGALOG

1)

CENELEC, PTB zone 0 as well as

III: 0 … 3000 pF

(VEGATOR Ex)

zone 0 and StEx Zone 10 and as
part of an overfill protection acc. to
WHG (VbF)

E18

2)

Continuous level measurement

I: 0 … 120 pF

470 kHz

VEGAMET

or level detection with potential

II: 0 … 600 pF

VEGALOG

separation according to the principle of

III: 0 … 3000 pF

(VEGATOR)

phase selective admittance proces-
sing especially for adhesive
products and for use in solids with
varying humidity

E18 Ex

2)

like E18, however for the use in

I: 0 … 120 pF

470 kHz

VEGAMET Ex

hazardous areas according to

II: 0 … 600 pF

VEGALOG

1)

CENELEC, PTB zone 0 as well as

III: 0 … 3000 pF

(VEGATOR Ex)

zone 0 and StEx zone 10 and as
part of an over fill protection acc. to
WHG (VbF)

1)

with safety barrier

2)

see following page

Product description