VEGA VEGATOR 622 User Manual

Page 7

Advertising
background image

VEGATOR 620 … 622

7

Product description

Ambient conditions

Permissible ambient temperature

-20°C … +60°C

VEGATOR 620: With an operating voltage of
60 V DC … 72 V DC the permissible ambient
temperature declines linearly from 60°C to
40°C.

Storage and transport temperature

-40°C … +70°C

Option

specially protected (tropicalised) electronics

Indicating elements

LED in front plate

green on: operating voltage on
yellow: switching point control
red: fault signal

Functions

Mode (selectable)

overfill protection (A)
dry run protection (B)

Integration time (adjustable)

0.2 … 20 sec.

Adjustment elements

Front plate

one or two potentiometers with scale 0 … 10
for switching point adjustment

On top cover, to the side

DIL for adjustment of:
- mode A/B
(A = overfill protection, B = dry run protection)
- integration time
- switch on/off delay

Electrical separation measures

Reliable separation acc. to
VDE 0106, part 1; between

power supply, measurement data input,

level relay and transistor output

- reference voltage

250 V

- insulation resistance

2.3 kV

- test voltage

2.3 kV

CE conformity

VEGATOR 620 … 622 signal conditioning instruments meet the protective regulations of
EMC (89/336/EWG) and NSR (73/23/EWG). The conformity has been judged acc. to the
following standards:
EMC

Emission

EN 50 081 - 1: 1992

Susceptibility

EN 50 082 - 2: 1995

NSR

EN 61 010 - 1: 1993

Advertising