1 product description, 1 function, 2 application features – VEGA VEGAFLEX 52K User Manual

Page 4

Advertising
background image

4

VEGAFLEX 52K

Product description

1 Product description

1.1 Function

High frequency microwave impulses are
guided along a steel rope.
The microwave impulses are reflected when
reaching the product surface. The impulse
running time is processed by the integrated
electronics and outputted as level.

The sensors detect levels in all types of sol-
ids. Density, conductivity and dielectric value
of the product do not influence the measure-
ment. Also, varying product properties can-
not influence the measured value.

Lime, cement, cereals, plastic granules, flour,
gravel - VEGAFLEX microwave sensors
solve the most difficult application problems
involving solids. Even in products with vary-
ing moisture or fluctuating dielectric constant,
the level is reliably detected. High, narrow
vessels in which a non-contact measuring
technique often delivers less than optimum
measuring results, can be measured without
problem by VEGAFLEX. VEGAFLEX 52 is
equipped with a cable of 8 mm diameter and
is available up to a length of 20 m.

• Adjustment without filling or emptying of the

vessel.

• 4 … 20 mA two-wire sensors, supply and

measuring signal via one two-wire cable
(loop powered).

• Up to 15 sensors can be connected via

one two-wire cable.

• Measuring range up to 20 m with small min.

distance.

• Unaffected by application conditions such

as:
- dust and noise generation
- moisture changes
- varying products

• Existing cable systems can be still used in

four-wire technology.

• Unaffected by the vessel material, e.g.

metal, concrete, plastic etc.

• As an option, the display with adjustment

can be separated from the sensor.

• Connection to all bus systems: Modbus,

Interbus S, Siemens 3964R, Profibus DP,
Profibus FMS, ASCII.

• Low wiring costs by using bus systems or

two-wire technology.

1.2 Application features

Applications

• Level measurement of solids.
• Measurement also in vacuum.
• All slightly conductive substance and all

substances with a dielectric value

e

r

> 1.8

can be measured.

• Measuring range 0 ... 20 m.

Two-wire technology

• Supply, signal transmission and output

signal on one two-wire cable.

• 4 … 20 mA output signal or digital output

signal.

Rugged

• Highly resistant materials: PA, 1.4401.

Precise and reliable

• Resolution 1 mm.
• Unaffected by noise, steam, dusts, gas

compositions and inert gas stratification.

• Unaffected by varying density.
• Measurements under pressure up to

16 bar and with product temperatures up
to 120°C.

Communicative

• Integrated display of measured values.
• As an option, display can be separated

from the sensor.

• Adjustment from the PLC level.

Approvals

• Ex Zone 0

- EExd ia IIC
- EEx ia IIC

• ATEX
• StEx Zone 10

Advertising