5 technical data – VEGA VEGAFLEX 52K User Manual

Page 8

Advertising
background image

8

VEGAFLEX 52K

The min. supply voltage depends on the sensor current.

0

4

22

mA

14

15

36

V

Range of the required
terminal voltage on the
sensor

Sensor current

Product description

1.5 Technical data

Power supply

Supply voltage
- two-wire sensor

24 V DC (15 … 36 V DC)

- four-wire sensor

24 V DC (20 … 72 V)
230 V AC (20 … 250 V), 50/60 Hz
fuse 0.315 A TR

Current consumption
- two-wire sensor

max. 22.5 mA

- four-wire sensor

max. 60 mA

Power consumption
- two-wire sensor

max. 810 mW

- four-wire sensor

max. 1.2 W

V

9

1000

680

500

250

0

20

22

24

26

28

30

32

34

36

15 16

18

Voltage limit
non Ex sensor

Voltage limit
Ex sensor

HART

®

load

Voltage supply

Measuring range

VEGAFLEX 52

0.3 ... 20 m

Output signal

4 … 20 mA current signal, load max. 500

W

Advertising