Calculation information for sensor length

The determination of the sensor length must be generally made with the respective expert.

Example: cylindrical tank

Procedure
-

calculate the level of the max. permissible volume 85 %,
e.g. 2400 mm

-

determine the distance from the flange lower edge up
to the calculated level

-

determine the total length of VEGASWING
L = distance + 25 mm
(25 mm = submerging depth up to the switch point)
in this example:
L = 600 m + 25 mm = 625 mm

A VEGASWING with a total length of 625 mm must be
ordered.

Note:
An increase of the total length of VEGASWING will cause
the instrument to respond even at low levels, a reduction
causes a response at higher levels.

If the required total length cannot be exactly determined,
the calculated value must be rounded up (determination to
the safe side).

3000 mm

L

0 mm

600 mm distance from
flange lower edge to the
determined switch point

Volume 85 %
corresponds to 2400 mm