2 sensor vegaswing 83 w5 ex with oscillator e86 ex, 4 dimensional drawings, 1 vegaswing 83 w5 ex – VEGA VEGATROL 10 Ex 1 User Manual

Page 8

Advertising
background image

VEGATROL 10 Ex 1

8

2 Technical Information

2.3.2 Sensor VEGASWING 83 W5 Ex with oscillator E86 Ex

Supply and signal circuit

Power supply

12 … 18,9 V DC
(from signal conditioning instrument VEGATOR 526 W Ex)

Data transmission

analog, 4 … 20 mA

Flame proofing

EEx ia IIC, T4

Internal effective capacitance

C

int

unimportant

Internal effective inductance

L

int

unimportant

Power consumption

tuning fork uncovered

approx. 7 mA

tuning fork coverd

10 … 20 mA

Fault signal

approx. 25 mA

Reference value

approx. 15 mA

Connection line

2-wire

Ambient conditions

Permissible operating temperature

-30

°

C … +70

°

C

Storage and transport temperature

-40

°

C … +80

°

C

Operating pressure

max. 25 bar
however observe max. permissible pressure of the flange

Electrical connection

Terminals in plastic housing

for connection of max. 1,5 mm

2

Cable entry

Pg 13,5

Electrical protective measures

Protection

IP 67

Protection class

II

Mechanical data

Material

Mounting parts

stainless steel 1.4571

Extension tube

stainless steel 1.4571

Tuning fork

stainless steel 1.4581

Resonance frequency of the tuning fork in air

approx. 380 Hz

Dimensions

see dimensional drawing

2.4

Dimensional drawings

2.4.1 VEGASWING 83 W5 Ex

(approx. dimensions in mm)

80x110

75

39

25

approx. 30

Switch point

L (min. 200, max. 3000)

Advertising