VEGA VEGATROL 10 Ex 1 User Manual

Page 7

Advertising
background image

VEGATROL 10 Ex 1

7

Electrical protective measures

Protection

unassembled

IP 00

installed in

carrier type 596 Ex with Ex-module
front completely equipped ......................... IP30
upper and lower side ................................ IP20
wiring side rear

................................ IP00

installed in

housing type 589 - 10 Ex ........................... IP30
(in both cases observe the respective TIB)

Protection class

II (in housing 589)

Overvoltage category

II

Mechanical data

Series

Module unit for carrier type 596 Ex or
housing 589 - 10 Ex

Dimensions unassembled

W = 50,8 mm (10 TE), H = 128,4 mm, D = 162 mm

Dimensions in plastic housing 589

W = 62,5 mm, H = 136 mm, D = 222 mm

Weight

approx. 400 g

VEGATOR 526 W Ex must only be connected to instruments in which no higher voltages than AC 250 V (50 Hz) occur.

Potential stages and galvanic separation

2 Technical Information

Voltage supply

P1

P3

P4

P5

P2

Meas. data input

Power sup. unit

P1 … P5
Potential stages

Microcomputer control and output

Relay contacts

Relay contacts

Sensor
Ex-area

Fail safe relay

Level relay

Advertising