VEGAMET 407 AF/AFT

Electrical connection

The electrical connections should be made on the
mounting assembly in accordance with the diagram
located on the back of the instrument.

Standard two-wire cable can be used as measuring
line, electrode and signal conditioning instrument.

If electromagnetic interferences have to be
expected, screened cable must be used.

As factory preset, the terminals 3 and 4 are bridged
(supply voltage for oscillator: 22 V DC)

Attention:
In conjunction with oscillator type 117 the bridge
must be removed!
(Therefore supply voltage for oscillator: 12 V DC)

Protective measures:
If there is a danger of voltage spikes overvoltage
arresters are recommended.
Note TIB "Overvoltage arresters" for connection.

18

17

16

15

14

13

N

L1

9

2

1

+

-

-

+

-

+

5

7

+

1

4 … 20 mA

8

6

0 … 20 mA

2

1

2

1

3

4

Output

1

2

3

Indicated

Current

Voltage

Voltage

value

output

output

output

0 %

0 / 4 mA

0 V

0 V

100 %

+ 20 mA

- 5 V

- 5 V

Relay output
(fail safe)

Mains connection

Voltage output 0 … 10 V

Voltage output 0 … 5 V

Current output 0/4 … 20 mA

Wiring bridge

Measuring line

Electrode with
oscillator

Pressure sensor
with oscillator