1 product description, 1 function, configuration and mounting, Function – VEGA VEGATRENN 547 V Ex User Manual

Page 3: Configuration, Mounting

Advertising
background image

VEGATRENN 547 V Ex

3

Product description

1 Product description

1.1 Function, configuration and

mounting

Function

Ex-separator VEGATRENN 547 V Ex is used
for intrinsically safe, galvanically isolated
supply of up to two ultrasonic or radar
sensors. At the input side it is connected to
the two-wire-VBUS-line of the signal
conditioning instrument and provides at the
output side 2 x 2 ib-circuits. Each sensor is
supplied via two ib-circuits so that two
sensors can be connected to Ex-separator.

The Ex-separator can be used in conjunction
with the following signal conditioning
instruments or sensors:
- VEGAMET 514␣ V and 515␣ V
- EV-card of VEGALOG 571
- ultrasonic sensors VEGASON series 80
- radar sensors VEGAPULS series 64 and

series 80 for intrinscially safe supply “ib“.

The intrinsically safe ib-circuits are isolated as
well as from the not intrinsically safe circuits.

Configuration

Configuration

The Ex-separator VEGATRENN 547 V Ex is
designed in 19“-technology with 5 TE (= 25,4
mm). The connection is made via a multiple
plug acc. to DIN 41 612.

Mounting

There are the following mounting possibilities
- in housing type 506 with VEGAMET
- in carrier BGT 596 Ex with VEGAMET
- carrier BGT LOG 571 *) with VEGALOG

Example 1:
In housing type 506 with VEGAMET

Fig. 1.1: Block diagram of the Ex-separator

Power supply

Intrinsically safe ib-
circuits

Sensor 1

Sensor 2

Signal
conditioning
instrument
(VBUS)

electronics

VEGAMET

515V

VEGATRENN

548VEx

Not-Ex-area

Ex-area

two
VBUS ib IIB-
circuits per
sensor

Supply

VEGATRENN
547␣ V Ex

VEGAMET
514␣ V
515␣ V

*) If several VEGATRENN 547 V Ex are used, it is

recommended to separate them into the cheaper
BGT 596 Ex.