VEGA-ASCII signal output VEGASCAN 850

5

Enquiry of measured values

3 Enquiry of measured values

3.1 Enquiry as single value

Low resolution

This telegram reads a DCS value out of VEGASCAN 850.

Answer from VEGASCAN 850

Start character: S1 = 1 character "=“
Start character: S2 = 1 character "#“
Total length of the telegram: 12 or 13 characters

Telegram from processing system to VEGASCAN 850

Identifier: 1 character, "%“
End identification: 1 character Chr (13) = CR = Carriage Return
Total length of the telegram: 5 characters

1 repetition

1 2 3 4 5 6

3 positions in front of the comma
1 decimal point
1 position after the comma

"-“ with negative values
" " with positive values

valid measured value

1 2 3 4 5

‘FAULT’

Fault

DCS

DCS

End

S1

no.

S2

value2

identification

Number of bytes

1

3

1

5-6

2

Range (ASCII)

=

001..060

#

DCS value or

fault

%CR

Example

=

001

#

-067.3

%CR

DCS

End

Identifier

number

identification

Number of bytes

1

3

1

Range (ASCII)

%

001..060

CR

Example

%

001

CR