VEGA VEGAMET 602 User Manual

Page 7

Advertising
background image

VEGAMET 601, 602

7

Ambient conditions

Permissible ambient temperature

-20°C … +60°C

Storage and transport temperature

-40°C … +70°C

Current output

Number

1 output

Function

analogue output of the evaluated data

Range

0/4 … 20 mA

Load

max. 500 Ohm

Resolution

0.05 % of range

Linearity error

0.05 % of range

Temperature error

0.08 %/10 K of range

Voltage output

Number

1 output

Function

analogue output of the evaluated data

Range

0 … 10 V

Current

max. 1 mA

Resolution

0.05 % of range

Linearity error

0.05 % of range

Temperature error

0.08 %/10 K of range

Relay output (only with VEGAMET 602)

Number

1 output

Contact

1 floating spdt each
AgNi and hard gold plated

Turn-on voltage

min. 10 mV DC
max. 250 V AC, 60 V DC

Switching current

min. 10 µA DC
max. 3 A AC, 1 A DC

Breaking capacitance

max. 500 VA, 54 W

Indicating elements

LED in front plate

green on: operating voltage on
red: fault signal (only on VEGAMET 602)

Analogue indication

11 segments, 0 % … 100 %

Functions

Integration time

0 … 20 sec.

Adjustable current output

0 … 20 mA/4 … 20 mA

Adjustment elements

On front plate

two potentiometers for adjustment of the
empty and full adjustment

On top, laterally

DIL switch
- adjustment of the current output

0 … 20 mA/4 … 20 mA

- integration time

Product description

Advertising