2 Technical Information
2
Technical Information
2.1
Technical data
Power supply
Operating voltage
Value
Tolerance
Frequency
Standard
220 V AC
+15 % –10 %
50 / 60 Hz
230 V AC
+10 % –15 %
50 / 60 Hz
Options
110 V AC
130 V AC
+15 % –10 %
50 / 60 Hz
240 V AC
24 V AC
42 V AC
+15 % –10 %
50 / 60 Hz
48 V AC
16 … 60 V DC
–––
–––
Power consumption at U
N
approx. 5 VA
Input data
Current input
Standard
0 … 20 mA; Ri = 100 Ohm
or
Voltage input
0 … 5 V / 10 V; Ri
≥
100 kOhm
Indication
LED-digits
3
1
/
2
-digit, 0000 … 1000
Height of digits
13,5 mm
Temperature range
Permissible ambient temperature
–20
°
C … +50
°
C
Storage and transport temperature
–20
°
C … +70
°
C
Protection
Terminals
IP 00
Housing
IP 20
Connection terminals
5-wire plug with terminal max. 1 x 1,5 mm
2
Weight
approx. 300 g
2.2
Dimensional drawings
42,5
112
96
48
123
5
20
90
0 0 0 0
91
43
Front panel cut-out