10
VEGAPULS 43 – Profibus PA
2
3
3
PACTware
SPS
Adr. 10
Adr. 1
Master-Class 1
Adr. 58
Adr. 60
Adr. 57
Adr. 59
Adr. 24
Adr. 23
Adr. 22
Adr. 21
Adr. 25 … 56
PA-
Adr. 25
Adr. 26
Adr. 27
Adr. 28
Adr. 29
DP-Bus
Product description
Profibus DP interface card as
Master-Class 2 (e.g. Softing)
Segment couple
(max. 32 participants)
Adjustment of the VEGAPULS radar sensors from process control via a Profibus interface card in the process
control computer or in an additional PC. The adjustment software VEGA Visual Operating (VVO) accesses the
sensors bidirectionally via the interface (interface card).