VEGA VEGAVIB 55 - double relay (DPDT) User Manual

Page 27

Advertising
background image

Integration time
- when immersed

approx. 0.5 s

- when laid bare

approx. 1 s

Ambient conditions
Ambient temperature on the housing

-40 … +80 °C (-40 … +176 °F)

Storage and transport temperature

-40 … +80 °C (-40 … +176 °F)

Process conditions
Parameter

Limit level of solids

Process pressure

-1 … 6 bar/-100 … 600 kPa (-14.5 … 87 psi)

Process temperature

-50 … +100 °C (-58 … +212 °F)

Density

>0.08 g/cm³ (0.003 lbs/in³)

Electromechanical data
Cable entry/plug (dependent on the version)
- Single chamber housing

l

1x cable entry M20x1.5 (cable-ø 5 … 9 mm),

1x blind stopper M20x1.5; attached 1x

cable entry M20x1.5

or:

l

1x cable entry ½ NPT, 1x blind stopper

½ NPT, 1x cable entry ½ NPT

or:

l

1x plug M12x1, 1x blind stopper M20x1.5

Spring-loaded terminals

for wire cross-section up to 1.5 mm²

(0.0023 in²)

Adjustment elements
Mode switch
- min.

Min. detection or dry run protection

- max.

Max. detection or overfill protection

Voltage supply
Supply voltage

20 … 253 V AC, 50/60 Hz, 20 … 72 V DC (at

U >60 V DC, the ambient temperature can be

max. 50 °C/122 °F)

Power consumption

1 … 8 VA (AC), approx. 1.3 W (DC)

VEGAVIB 55 - - double relay (DPDT)

27

Supplement

29301

-EN

-070109

Advertising