VEGA VEGAVIB 62 - two-wire User Manual

Page 20

Advertising
background image

Mode on the
sensor

Level

Signal current -
Sensor

Signal lamp -
sensor

Max.
Overflow protec-
tion

8 mA

Green

Max.
Overflow protec-
tion

approx. 16 mA

Red

Min.
Dry run protection

approx. 8 mA

Green

Min.
Dry run protection

approx. 16 mA

Red

Fault message
(min./max. mode)

any

<

2.3 mA

flashes red

VEGAVIB 62 level switch with signal conditioning instrument

1

)

The following chart provides an overview of the switching conditions
depending on the adjusted mode of the signal conditioning instrument
and the level.

Note:
Keep in mind that the mode switch of VEGAVIB 62 must be always set
to "max.".

Mode on the
signal condi-
tioning in-
strument

Level

Signal cur-
rent - Sensor

Signal lamp -
sensor

Signal lamp -
signal condi-
tioning in-
strument

Mode A
Overflow pro-
tection

approx. 8 mA

Green

1)

You will find suitable signal conditioning instruments in chapter "Technical
data".

20

VEGAVIB

62 • - two-wire

6 Set up

29274