10 supplement, 1 technical data – VEGA VEGASON 63 Foundation Fieldbus User Manual

Page 40

Advertising
background image

40

10 Supplement

VEGASON 63 • Foundation Fieldbus

28792-EN-130417

10 Supplement

10.1 Technical data

General data
Materials, wetted parts

Ʋ Process fitting

UP (glass-fibre reinforced polyester resin)

Ʋ Transducer diaphragm

316Ti

Ʋ Seal transducer diaphragm/process

fitting

EPDM

Materials, non-wetted parts

Ʋ Mounting strap

1.4301

Ʋ Compression flange

PPH, 316L

Ʋ Housing

Plastic PBT (polyester), Alu die-casting powder-coated,

316L

Ʋ Seal between housing and housing

cover

NBR (stainless steel housing), silicone (Alu/plastic hous-

ing)

Ʋ Inspection window in housing cover

Polycarbonate

Ʋ Ground terminal

316Ti/316L

Weight

2.7 … 5.7 kg (6 … 12.6 lbs), depending on the process

fitting and housing

Output variable
Output

Ʋ Signal

digital output signal, Foundation Fieldbus protocol

Ʋ Physical layer

according to IEC 61158-2

Cycle time

min. 1 s (dependent on the parameter setting)

Ʋ Damping (63 % of the input variable) 0 … 999 s, adjustable

Ʋ Met NAMUR recommendation

NE 43

Channel Numbers

Ʋ Channel 1

Primary value

Ʋ Channel 2

Secondary value 1

Ʋ Channel 3

Secondary value 2

Transmission rate

31.25 Kbit/s

Current value

10 mA, ±0.5 mA

Resolution, digital

> 1 mm (0.039 in)

Input variable
Measured variable

distance between lower edge of the transducer and

product surface

Measuring range

Ʋ Liquids

up to 15 m (49.21 ft)

Ʋ Bulk solids

up to 7 m (22.97 ft)

Dead band

0.6 m (1.969 ft)

Advertising