6 Set up

6.1 General

The numbers in brackets refer to the following illustrations.

On the electronics module you will find the following indicating

and adjustment elements:

l

Potentiometer for switching point adaptation (1)

l

DIL switch for mode adjustment - min./max. (2)

l

Signal lamp (5)

Note:

As a rule, always set the mode with mode switch (2) before

starting the setup of VEGAVIB 67 . If the instrument is used in

conjunction with a signal conditioning instrument, always set

the mode switch (2) on VEGAVIB 67 to max. mode.
The mode is selected on the signal conditioning instrument

with the mode switch.
The switching output will change if you set one of the two mode

switches afterwards. This could possibly trigger other con-

nected instruments or devices.