background image

Mode on the

sensor

Level

Signal current -

Sensor

Signal lamp -

sensor

Fault signal

(min./max. mode)

any

<2.3 mA

flashes red

VEGAVIB 67 level switch with signal conditioning instru-

ment

1)

The following chart provides an overview of the switching

conditions depending on the adjusted mode of the signal

conditioning instrument and the level.

Note:

Keep in mind that the mode switch of VEGAVIB 67 must be

always set to "max.".

Mode on the

signal condi-

tioning in-

strument

Level

Signal cur-

rent - Sen-

sor

Signal lamp

- sensor

Signal

lamp - sig-

nal condi-

tioning in-

strument

Mode A

Overfill pro-

tection

approx. 8 mA

Green

Mode A

Overfill pro-

tection

approx.

16 mA

red

Mode B

Dry run pro-

tection

approx.

16 mA

red

Mode B

Dry run pro-

tection

approx. 8 mA

Green

1)

You will find suitable signal conditioning instruments under "Technical data"