3 wiring plan, single chamber housing – VEGA VEGACAP 62 - two-wire User Manual

Page 16

Advertising
background image

16

5 Connecting to power supply

VEGACAP 62 • - two-wire

30007-EN-130916

Fig. 8: Connection steps 5 and 6

6. Insert the wire ends into the open terminals according to the wir-

ing plan

7. Press down the opening levers of the terminals, you will hear the

terminal spring closing

8. Check the hold of the wires in the terminals by lightly pulling on

them

9. Tighten the compression nut of the cable entry. The seal ring must

completely encircle the cable

10. If necessary, carry out a fresh adjustment
11. Screw the housing cover back on
The electrical connection is hence finished.

5.3 Wiring plan, single chamber housing

1

4

4

4

2

3

Fig. 9: Material versions, single chamber housing
1 Plastic (not with dust-Ex)

2 Aluminium

3 Stainless steel

4 Filter element for pressure compensation or blind plug with version IP 66/

IP 68, 1 bar

Housing overview

Advertising