6 setup, 1 general information, 2 adjustment elements – VEGA VEGACAP 62 - two-wire User Manual

Page 19

Advertising
background image

19

6 Setup

VEGACAP 62 • - two-wire

30007-EN-130916

6 Setup

6.1 General information

The figures in brackets refer to the following illustrations.

On the electronics module you will find the following display and

adjustment elements:

DIL switch for measuring range selection

Control lamp

Note:

As a rule, always set the mode with the mode switch of the signal

conditioning instrument before starting setup VEGACAP 62. The

switching output will change if you set the mode switch afterwards.

This could possibly trigger other connected instruments or devices.

6.2 Adjustment elements

4

1

2

3

Fig. 14: Electronics module - Two-wire output
1 DIL switch for measuring range selection (with compensation button)

2 Ground terminal

3 Connection terminals

4 Control lamp

A failure can be displayed with closed housing (only plastic housing),

see operating instructions manual of the "Signal conditioning instru-

ment".
Note:

Screw the housing cover tightly up to the thread stop so that the

inspection glass is above the control lamp (LED).
To adjust VEGACAP 62, first of all remove the housing cover.

With the potentiometer on the signal conditioning instrument and

the measuring range selection switch (1) on VEGACAP 62 you can

Function/Configuration

Measuring range selec-

tion switch (1)

Advertising