10.1 Technical data

General data

316L corresponds to 1.4404 or 1.4435

Materials, wetted parts

-

Process fitting

316L, Hastelloy C22 plated

-

Antenna

316L, Hastelloy C22

-

Antenna cone

PTFE (TFM 1600), ceramic (99.7 % AL

2

O

3

)

-

seal, antenna system

FKM (Viton), FFKM (Kalrez 6375), FEP FKM (Viton)
coated, EPDM (FDA-approved), graphite

Materials, non-wetted parts

-

Housing

Plastic PBT (polyester), Alu die-casting powder-
coated, 316L

-

Seal between housing and housing
cover

NBR (stainless steel housing), silicone (Alu/plastic
housing)

-

Inspection window in housing cover for
PLICSCOM

Polycarbonate (UL-746-C listed)

-

Ground terminal

316Ti/316L

Weight, depending on flange size, pressure
stage and housing material

6.3 … 136 kg (13.89 … 299.8 lbs)

Output variable

Output

-

Signal

digital output signal, Foundation Fieldbus protocol

-

Physical layer

according to IEC 61158-2

Channel Numbers

-

Channel 1

Primary value

-

Channel 2

Secondary value 1

-

Channel 3

Secondary value 2

Transmission rate

31.25 Kbit/s

Current value

10 mA, ±0.5 mA

Damping (63 % of the input variable)

0 … 999 s, adjustable

Input variable

Measured value

distance between process fitting and product sur-
face

Min. distance from antenna end

100 mm (4 in)

Measuring range

up to 35 m (114.83 ft)