4 M

ounting

4

.1 General instructions

The note of the following general safety instructions:

l

Dismount the lock fitting only in unpressurized condition

l

Use only suitable graphite gasket rings (article no.
2.29849). Make sure that the graphite gasket rings are not
damage. Damaged rings are no longer tight. If you are not
sure, use new rings.

l

Only use approved hexagon screws DIN 912 M6 x 25 of
A4-70 according to AD leaflet W2. The corresponding
spring rings B6 must be made of A4 according to DIN 7980.

l

Grease the thread and the support of the terminal screws
with a suitable lubricant. The lubricant must be suitable for
material combination 316L/316L and for a temperature
range of -50 … +250°C (-58 … +482°F) e.g. Varybond
type NSS-16/7. The threads are already supplied with a
lubricant.

4

.2 Mounting sequence

The lock fitting is already premounted.

The numbers in brackets refer to the following illustration.

1

Loosen the screw (6) and remove the locking bracket (4)

2

Screw mounting boss (7) with a resistant seal ring into the
thread of the vessel and tighten the mounting boss (7) on
the hexagon (SW 41 or SW 60)

3

Clean the connection tube of the sensor and the surfaces
of the clamp (1) as well as the pressure screw (11)
carefully and remove grease, oil and dirt. Insert the sensor
into the lock fitting. Slide the tube into the requested
position and hold it

4

Make sure that the sensor is in the correct position (height).
The height adjustment of the sensor determines also the
switching point

5

Tighten the pressure screw (11) with a torque 70 ±10 Nm
(51 ±7 lbf ft)

6

Continue to turn the pressure screw (11) clockwise until the
hexagon surfaces of the pressure screw (11) and the
mounting boss (7) correspond (max. 1/6 turn)

7

Tighten the terminal screws (3) alternately. Make sure that
the gap between clamp and pressure screw is in parallel.
Tighten the terminal screws with a defined torque.

8

Lock fitting ARV-SG63.2 • - pressure range: -1 … 16 bar

4 Mounting

29751

-EN

-081013