Service, Info – VEGA VEGAPULS 62 (≥ 2.0.0 - ≤ 3.8) standpipe ver. Foundation Fieldbus User Manual
Page 36
3.1
Pointer
Distance min.: 0.234 m(d)
Distance max.: 5.385 m(d)
3.2
Meas. reliability
15 dB
Sensor status
OK
3.3
Curve selection
Echo curve
▼
3.4
Echo curve
Presentation of the echo
curve
Service
4
Basic adjustment
Display
Diagnostics
▶
Service
Info
4.1
Gating out of false signals
Change now?
4.2
Extended setting
None
▼
Quick level change
▼
4.4
Simulation
Start simulation?
▼
4.4
Sensor length
5 m(d)
4.5
Reset
Reset now?
4.7
Unit of measurement
m(d)
▼
4.8
Language
Deutsch
▼
4.8
Copy sensor data
Copy sensor data?
4.9
PIN
Enable?
Info
5
Basic adjustment
Display
Diagnostics
Service
▶
Info
5.1
Sensor type
Serial number
12345678
5.2
Date of manufacture
21. January 2009
Software version
3.50
5.3
Last change using PC
21. January 2009
5.4
Sensor characteristics
Display now?
36
VEGAPULS
62 standpipe version • Foundation Fieldbus
6 Set up with the indicating and adjustment module PLICSCOM
28740
-EN
-090305