VEGA VEGAPULS 66 (≥ 2.0.0 - ≤ 3.8) standpipe ver. 4 … 20 mA_HART two-wire User Manual

Page 46

Advertising
background image

M

in. distance

0

mm

M

easuring range

up to 5.85 m (19.19 ft)

3)

Reference conditions to measuring accuracy (similar to DIN EN 60770-1)

R

eference conditions according to DIN EN 61298-1

-

T

emperature

+

18 … +30 °C (+64 … +86 °F)

-

R

elative humidity

45 … 75 %

-

A

ir pressure

860 … 1060

mbar/86 … 106 kPa (12.5 … 15.4 psig)

O

ther reference conditions

-

R

eflector

ideal reflector, e.g. metal plate 2 x 2 m

-

F

alse reflections

B

iggest false echo, 20 dB smaller than the useful

echo

Characteristics and performance data

F

requency

C-

band (6 GHz technology)

S

tep response or adjustment time

4)

>

1

s (dependent on the parameter setting)

M

ax. level change

adjustable up to 1 m/min. (dependent on the
parameter adjustment)

M

ax. emitted HF power of the antenna system

-

P

ulse peak power approx.

0.1

mW

-

P

ulse duration

<

2

ns

-

SAR

value

5)

0.471

mW/kg

Measuring accuracy

R

esolution, general

max. 1 mm (0.039 in)

D

eviation

6)

see diagrams

3)

A

ccording to the respective standpipe length.

4)

T

ime to output the correct level (with max. 10 % deviation) after a sudden

level change.

5)

at the aperture of a horn antenna with ø 150 mm

6)

I

ncl. non-linearity, hysteresis and non-repeatability.

46

VEGAPULS

66

standpipe version • 4 … 20 mA/HART two-wire

10 S

upplement

28741

-EN

-090305