4 Mounting
VEGASWING 63 • - NAMUR
29231-EN-130409
1
Fig. 3: Mounting horizontal
1 Switching point
1
2
Fig. 4: Horizontal installation (recommended mounting position, particularly for
adhesive products)
1 Switching point
2 Marking with screwed version on top, with flange versions directed to the
flange holes
With flange versions, the fork is directed as follows to the flange holes.
Fig. 5: Fork position with flange versions
Use the recommended cables (see chapter "Connecting to power
supply") and tighten the cable gland.
You can give your instrument additional protection against moisture
penetration by leading the connection cable downward in front of the
cable entry. Rain and condensation water can thus drain off. This ap-
plies mainly to outdoor mounting as well as installation in areas where
high humidity is expected (e.g. through cleaning processes) or on
cooled or heated vessels.
Moisture