5 Connecting to power supply

VEGASWING 63 • - NAMUR

29231-EN-130409

8. Check the hold of the wires in the terminals by lightly pulling on

them

9. Tighten the compression nut of the cable entry. The seal ring must

completely encircle the cable

10. Screw the housing cover back on
The electrical connection is hence finished.

5.3 Wiring plan, single chamber housing

The following illustrations apply to the non-Ex as well as to the Ex-d

version.

1

4

4

4

2

3

Fig. 10: Material versions, single chamber housing
1 Plastic (not with EEx d)

2 Aluminium

3 Stainless steel (not with EEx d)

4 Filter element for pressure compensation or blind plug with version IP 66/

IP 68, 1 bar (not with EEx d)

N

NAMUR

(IEC 60947-5-6)

max.

min.

Simul.

+ -

0,5 g / cm3

0,7 g / cm3

3

6

5

7

1

2

4

Fig. 11: Electronics and connection compartment, single chamber housing
1 Control lamp

2 DIL switch for characteristics reversal

3 DIL switch for sensitivity adjustment

4 Ground terminal

5 EMC filter element

6 Simulation key

7 Connection terminals