VEGA VEGASWING 61 - two-wire User Manual

Page 16

Advertising
background image

16

5 Connecting to power supply

VEGASWING 61 • - two-wire

29227-EN-130409

"Technical data", "Ex-technical data" are available in the supplied

"Safety information manual".
The wiring example is applicable for all suitable signal conditioning

instruments.
The control lamp on VEGASWING 61 lights in general

red - with covered tuning fork

green - with uncovered tuning fork

Take note of the operating instructions manual of the signal condition-

ing instrument. Suitable signal conditioning instruments are listed in

chapter "Technical data".
If VEGASWING 61 is used in Ex areas as part of an overfill protection

system according to WHG (Water Resources Act), take note of the

regulations in the safety instructions and conformity certificates. If the

instrument with electronics module SWE60Z EX, SWE60Z EX E1

is to be operated directly on the analogue input of a PLC, a suitable

safety barrier should be connected.

4

3

2

1

1 2

+

-

Fig. 10: Wiring plan, single chamber housing

5.4 Wiring plan - version IP 66/IP 68, 1 bar

1

2

Fig. 11: Wire assignment, connection cable
1 brown (+) and blue (-) to power supply or to the processing system

2 Shielding

Wire assignment, con-

nection cable