10 supplement, 1 technical data – VEGA VEGASON 61 Profibus PA User Manual

Page 41

Advertising
background image

41

10 Supplement

VEGASON 61 • Profibus PA

28784-EN-130417

10 Supplement

10.1 Technical data

General data
Materials, wetted parts

Ʋ Process fitting, transducer

PVDF

Ʋ Seal between transducer and process

fitting

EPDM, FKM (Viton)

Materials, non-wetted parts

Ʋ Housing

Plastic PBT (polyester), Alu die-casting powder-coated,

316L

Ʋ Seal between housing and housing

cover

NBR (stainless steel housing), silicone (Alu/plastic hous-

ing)

Ʋ Inspection window in housing cover

Polycarbonate

Ʋ Ground terminal

316Ti/316L

Weight

1.8 … 4 kg (4 … 8.8 lbs), depending on the process

fitting and housing

Max. torque mounting boss

25 Nm

Output variable
Output signal

digital output signal, format according to IEEE-754

Cycle time

min. 1 s (dependent on the parameter setting)

Sensor address

126 (default setting)

Current value

10 mA, ±0.5 mA

Damping (63 % of the input variable)

0 … 999 s, adjustable

Met NAMUR recommendation

NE 43

Resolution, digital

> 1 mm (0.039 in)

Input variable
Measured variable

distance between lower edge of the transducer and

product surface

Measuring range

Ʋ Liquids

up to 5 m (16.4 ft)

Ʋ Bulk solids

up to 2 m (6.562 ft)

Dead band

0.25 m (0.82 ft)

Reference conditions to measuring accuracy (according to DIN EN 60770-1)
Reference conditions according to DIN EN 61298-1

Ʋ Temperature

+18 … +30 °C (+64 … +86 °F)

Ʋ Relative humidity

45 … 75 %

Ʋ Air pressure

860 … 1060 mbar/86 … 106 kPa (12.5 … 15.4 psig)

Other reference conditions

Ʋ Reflector

ideal reflector, e.g. metal plate 2 x 2 m (6.56 x 6.56 ft)

Ʋ False reflections

Biggest false signal, 20 dB smaller than the useful signal

Advertising