VEGA VEGAFLEX 63 Foundation Fieldbus User Manual
Page 43
Advertising
L
0
-3 mm
(-0.118
")
3 mm
(0.118
")
15 mm
(0.591
"
)
-15 mm
(-0.591
")
0,2 m
(7.874
"
)
0,08 m
(3.15
"
)
0,04 m
(1.575
")
0,04 m
(1.575
")
1
1
Fig. 19: Deviation VEGAFLEX 63 in rod version in water
1
Dead zone - no measurement possible in this area
L
Probe length
L
5 mm
(0.197
")
0
-5 mm
(-0.197
")
15 mm
(0.591
"
)
-15 mm
(-0.591
"
)
-10 mm
(-0.394
")
0,35 m
(13.78
")
0,2 m
(7.874
"
)
0,1 m
(3.937
")
0,05 m
(1.969
")
1
1
Fig. 20: Deviation VEGAFLEX 63 in rod version in oil
1
Dead zone - no measurement possible in this area
L
Probe length
VEGAFLEX
63 • Foundation Fieldbus
43
10 Supplement
31844
-
EN
-100426
Advertising