Modes (adjustable)
-
A
Max. detection or overfill protection
-
B
Min. detection or dry run protection
Switching delay
approx. 0.5 … 20 s
Ambient conditions
Ambient temperature on the housing
-40 … +70 °C (-40 … +158 °F)
Storage and transport temperature
-40 … +80 °C (-40 … +176 °F)
Process conditions
Permissible process temperature
-40 … +100 °C (-40 … +212 °F)
Process pressure
-1 … 6 bar/-100 … 600 kPa (-14.5 … 87 psi)
Conductive of the medium
min. 5 µS/cm with 30 mm electrode covering
Electromechanical data
Cable gland
-
with transistor module
1x cable entry M20x1.5; 1x blind stopper
M
20x1.5
Screw terminals
for wire cross-section up to 1.5 mm²
(0.0023 in²)
Voltage supply
Supply voltage
10 … 55 V DC
Power consumption
max. 0.5 W
Electrical protective measures
Protection
-
Plastic housing
IP
66
-
Aluminium housing
IP
66/IP 67
Overvoltage category
II
Protection class
I