VEGA VEGAFLEX 67 (-40…+150°C) 4 … 20 mA_HART two-wire User Manual

Page 53

Advertising
background image

0 °C

(32 °F)

40 °C

(104 °F)

20 °C

(58 °F)

60 °C

(140 °F)

80 °C

(176 °F)

50 °C

(122 °F)

-40 °C

(-40 °F)

100 °C

(212 °F)

150 °C

(302 °F)

1

2

Fig. 28: Ambient temperature - Process temperature

1

Ambient temperature

2

Process temperature (depending on the seal material)

Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar

C

able entry/plug

3)

-

S

ingle chamber housing

l

1

x cable gland M20 x 1.5 (cable: ø 5 … 9 mm),

1

x blind stopper M20 x 1.5

or:

l

1

x closing cap M20 x 1.5; 1 x blind stopper

M

20

x 1.5

or:

l

1

x closing cap ½ NPT, 1 x blind plug ½ NPT

or:

l

1

x plug (depending on the version), 1 x blind

stopper M20 x 1.5

-

D

ouble chamber housing

l

1

x cable entry M20 x 1.5 (cable: ø 5 … 9 mm),

1

x blind stopper M20 x 1.5; 1 x blind stopper

M

16

x 1.5 or optionally available with 1 x plug

M

12

x 1 for external indicating and adjustment

unit

or:

l

1

x closing cap ½ NPT, 1 x blind stopper

½ NPT

, 1

x blind stopper M16 x 1.5 or

optionally 1 x plug M12 x 1 for external
indicating and adjustment unit

or:

l

1

x plug (depending on the version), 1 x blind

stopper M20 x 1.5; 1 x blind stopper M16 x 1.5
or optionally available with 1 x plug M12 x 1 for
external indicating and adjustment unit

3)

D

epending on the version M12 x 1, according to DIN 43650, Harting, 7/

8" FF.

VEGAFLEX

67 • 4 … 20

mA/HART - two-wire

53

10 S

upplement

31853

-

EN

-120329