4 switch on phase, Internal check of the electronics – VEGA VEGAWELL 51 4 … 20 mA_HART User Manual

Page 20

Advertising
background image

1

2

3

4

-

-

+

mA

+

1

2

1

2

1

2

3

+

+

Fig. 8: Terminal assignment VEGABOX 02

1

To power supply or the processing system (signal pressure transmitter)

2

For voltage supply or to processing system (resistance thermometer

PT 100)

3

Shielding

4

)

Wire number

Wire colour/Polarity

Terminal VEGABOX 02

1

brown (+)

1

2

blue (-)

2

3

S

hielding

G

round

Wire number

Wire colour/Polarity

Terminal temperature
transmitter

3

W

hite

1

4

Y

ellow

2

5

R

ed

3

6

B

lack

4

5

.4 Switch on phase

A

fter connecting VEGAWELL 51 to power supply or after a

voltage recurrence, the instrument carries out a self-check:

l

I

nternal check of the electronics

l

4 … 20

mA output jumps to the set failure signal

T

hen VEGAWELL 51 delivers a current of 4 … 20 mA to the

cable. The value corresponds to the actual level as well as to
settings already carried out, e.g. the factory setting.

4)

C

onnect screen to ground terminal. Connect ground terminal on the outside

of the housing as prescribed. The two terminals are galvanically connected.

Connection via
VEGABOX 02 with inte-
grated transmitter for
PT 100

20

VEGAWELL

51 • 4 … 20

mA/HART

C

onnecting to power supply

32468

-EN

-080604

Advertising