1 for your safety, 1 authorised personnel, 2 appropriate use – VEGA VEGASWING S 52 User Manual

Page 13: 3 warning about misuse, 4 general safety instructions, 5 ce conformity, 2 product description, 1 configuration, 2 principle of operation, Operating instructions

Advertising
background image

Operating instructions

1 F

or your safety

1

.1

Authorised personnel

All operations described in this operating instruc-
tions manual must be carried out only by trained
specialist personnel authorised by the plant oper-
ator.

During work on and with the device the required
personal protection equipment must always be
worn.

1

.2

Appropriate use

VEGASWING S 52 is a sensor for level detection.

You can find detailed information on the application
range of VEGASWING S 52 in chapter "Product
description
".

1

.3

Warning about misuse

Inappropriate or incorrect use of the instrument can
give rise to application-specific hazards, e.g.
vessel overfill or damage to system components
through incorrect mounting or adjustment.

1

.4

General safety instructions

This is a high-tech instrument requiring the strict
observance of standard regulations and guidelines.
The user must take note of the safety instructions in
this operating instructions manual, the country-
specific installation standards as well as all
prevailing safety regulations and accident preven-
tion rules.

The instrument must only be operated in a
technically flawless and reliable condition. The
operator is responsible for trouble-free operation of
the instrument.

During the entire duration of use, the user is
obliged to determine the compliance of the
required occupational safety measures with the
current valid rules and regulations and also take
note of new regulations.

1

.5

CE conformity

The protection goals of the EMC Directive 2004/
108/EC (EMC)

and the Low Voltage Directive

2006/95/EC (LVD)

are fulfilled.

Conformity has been judged according to the
following standards:

EMC: EN 61326-1: 2006
(

electrical instruments for control technology and

laboratory use - EMC requirements)

l

Emission: Class B

l

Susceptibility: Industrial areas

LVD: EN 61010-1: 2001
(

safety regulations for electrical measurement,

control and laboratory instruments - part 1: General
requirements)

2 P

roduct description

2

.1

Configuration

Scope of delivery
The scope of delivery encompasses:

l

VEGASWING S 52 point level sensor

l

Test magnet

l

Documentation

-

this operating instructions manual

-

WHG certificate

2

.2

Principle of operation

Area of application
VEGASWING S 52 is a point level sensor with
tuning fork for level detection.

It is designed for use in liquids in the food and
pharmaceutical industries.

Fault monitoring
The electronics module of VEGASWING S 52
continuously monitors via frequency evaluation the
following criteria:

l

Strong corrosion or damage on the tuning fork

l

loss of vibration

l

Line break to the piezo drive

VEGASWING S 52

13

For your safety

32948

-

01

-

080917

Advertising