VEGA VEGAFLEX 67 (-40…+150°C PFA insulated) Profibus PA User Manual

Page 46

Advertising
background image

TS

d1

h1

h2

d2

1

L2

L1

Fig. 19: Interface measurement (interface is between L1 and L2)

1

Reference plane

d1 Distance to the interface (Secondary Value 2)
d2 Distance to the level (Distance Level)
TS

Thickness of the upper medium (d1 - d2)

h1 Height - interface (Secondary Value)
h2 Height - Level
L1

Lower medium

L2

Upper medium

Resolution, digital

>

1 mm (0.039 in)

Accuracy (according to DIN EN 60770-1)

Process reference conditions according to DIN EN 61298-1

-

Temperature

+

18 … +30 °C (+64 … +86 °F)

-

Relative humidity

45 … 75 %

-

Air pressure

+

860 … +1060 mbar/+86 … +106 kPa

(+12.5 … +15.4 psig)

-

Emulsion phase

<

2 mm (< 0.079 in)

Installation reference conditions

-

Min. distance to installations

>

500 mm (19.69 in)

-

Vessel

metallic, ø 1 m (3.281 ft), centric installation,
process fitting flush with the vessel ceiling

-

Medium

Water/Oil (dielectric figure ~2.0)

-

Installation

Probe end does not touch the vessel bottom

Sensor parameter adjustment

Gating out of false signals carried out
In bulk solids applications, implementing a false
signal suppression is generally not recommended.
The accuracy of bulk solid applications depends

46

VEGAFLEX

67 • Profibus PA

10 Supplement

32305

-EN

-120329

Advertising