VEGA VEGAFLEX 67 (-40…+150°C PFA insulated) 4 … 20 mA_HART four-wire User Manual

Page 47

Advertising
background image

L

0

15 mm

(0.591

"

)

-15 mm

(-0.591

"

)

10 mm

(0.394

")

-10 mm

(-0.394

")

0,35 m

(13.78

")

0,2 m

(7.874

"

)

0,2 m

(7.874

")

0,05 m

(1.969

")

1

1

Fig. 19: Deviation VEGAFLEX 67 in cable version

1

Dead zone - no measurement possible in this area

L

Probe length

Influence of the ambient temperature to the sensor electronics
T

emperature drift

0.03 %/10 K

relating to the max. measuring range

or max. 0.3 %

T

emperature drift - Digital output

3

mm/10 K relating to the max. measuring range or

max. 10 mm

Ambient conditions

A

mbient, storage and transport temperature

-40 … +70 °C (-40 … +158 °F)

Process conditions

P

rocess pressure

-

F

lange version ≤ 2"/DN 50

-0.5 … +16

bar/-50 … +1600 kPa (-7.3 … +232 psig),

depending on the process fitting

-

F

lange version > 2"/DN 50

-0.2 … +16

bar/-20 … +1600 kPa (-2.9 … +232 psig),

depending on the process fitting

P

rocess temperature (flange temperature)

-40 … +150 °C (-40 … +302 °F)

T

he measurement error from the process condi-

tions is in the specified pressure and temperature
range of below 1 %.

VEGAFLEX

67 • 4 … 20

mA/HART - four-wire

47

10 S

upplement

32304

-

EN

-120329