2 profibus pa, 2 profibus pa – VEGA VEGAPULS 66 (≥ 2.0.0 - ≤ 3.8) enamel Profibus PA User Manual

Page 56

Advertising
background image

10.2 Profibus PA

Instrument master file
The instrument master file (GSD) contains the characteristic data of the Profibus PA instrument.
These data are, e.g. the permissible transmission rates as well as information on diagnostics values
and the format of the measured value outputted by the PA instrument.

A bitmap file is also provided for the Profibus network planning tool. This file is installed automatically
when the GSD file is integrated. The bitmap file is used for symbolic indication of the PA instrument in
the configuration tool.

Ident number
Each Profibus instrument gets an unambiguous ident number (ID number) from the Profibus user
organisation (PNO). This ID number is also included in the name of the GSD file. For VEGAPULS 66
the ID number is 0 x 0772(hex) and the GSD file PS__0772.GSD. Optionally to this manufacturer-
specific GSD file, PNO provides also a general so-called profile-specific GSD file. For VEGAPULS 66
you have to use the general GSD file PA139700.GSD. If the general GSD file is used, the sensor
must be set to the profile-specific ident number via the DTM software. By default, the sensor operates
with the manufacturer-specific ID number.

Cyclical data traffic
The master class 1 (e.g. PLC) cyclically reads out measured values from the sensor during operation.
The below block diagram below shows which data can be accessed by the PLC.

m(d)

%

Lin%

Min-Max

adjustment

Linearization

PROFIBUS PA-output

Primary

Value

Secondary

Value 2

Secondary

Value 1

Target

Mode

Failure

mode

Alarms

Scaling

Source for

scaling

t

i

Integration

Sensor

characteristics

PA-Out

TB

FB

Select additional cyclic

value

Fig. 34: VEGAPULS 66: Block diagram with AI (PA-OUT) value and additional cyclical value

TB Transducer Block
FB Function Block

56

VEGAPULS

66 enamel • Profibus PA

10 Supplement

33335

-EN

-090305

Advertising