9 supplement, 1 technical data, 9supplement – VEGA Float for oil_water detection for for VEGACAP 63 User Manual
Page 13
9
Supplement
9
.1 Technical data
Technical data
Following you find all data deviating from the standard instrument. All other technical data are
specified in the operating instruction of the respective sensor.
General data
Material 316L corresponds to 1.4404 or 1.4435
Materials, wetted parts
-
Float
PVC
-
Nut
PPH
-
Adapter
316L
-
Ground rod
316L
Weights
-
Float
approx. 2400 g (85 oz)
Suitable point level sensor - VEGACAP 63
-
Order length L - Point level sensor
160 mm
-
Housing material
Plastic
-
Electronics version
Two-wire electronics (Z)
-
Process fitting
G ¾ A
Suitable signal conditioning instru-
ments
VEGATOR
521, 621
Process conditions
Process temperature
-30 … +60 °C (-22 … +140 °F)
Approvals
The floating body can be used in Ex area zone 1 (ATEX II 2G).
There is a danger of static charging on the plastic floating body.
-
Avoid friction
-
No dry cleaning
-
Do not mount in areas with flowing,
non-conductive products
Float for oil/water detection • for VEGACAP 63
13
9 Supplement
31595
-
EN
-100604