5 menu schematic, Basic adjustment, Display – VEGA VEGACAL 69 4 … 20 mA_HART - two-wire User Manual
Page 28
28
6 Set up with the display and adjustment module PLICSCOM
VEGACAL 69 • 4 … 20 mA/HART - two-wire
31178-EN-130917
Function
Reset value
Damping ti
0 s
Linearization
Linear
Sensor-TAG
Sensor
Display
%
Current output - characteristics
4 … 20 mA
Current output - max. current
20.5 mA
Current output - min. current
3.8 mA
Current output - failure
< 3.6 mA
Special parameters
All special parameters are reset to delivery status.
Peak value
The min. and max. values are reset to the actual value.
6.5 Menu schematic
Basic adjustment
▶
Basic adjustment
1
Display
Diagnostics
Service
Info
Min. adjustment
1.1
0.00 %
=
0.0 pF
82.5 pF
Max. adjustment
1.2
100.00 %
=
1000.0 pF
327.4 pF
Damping
1.3
0 s
Linearization curve
1.4
Linear
Sensor-TAG
1.5
Sensor
Display
Basic adjustment
2
▶
Display
Diagnostics
Service
Info
Displayed value scaled
2.1
Unit
2.2
Volume
hl
Scaling
2.3
0 % = 000.5 hl
100 % = 005.0 hl
Backlight
2.4
Switched off
▼