10 Supplement

VEGACAL 69 • 4 … 20 mA/HART - two-wire

31178-EN-130917

10 Supplement

10.1 Technical data

General data
Material 316L corresponds to 1.4404 or 1.4435
Materials, wetted parts

Ʋ Process fitting - flange

PP or PTFE

Ʋ insulation (fully insulated)

FEP

Materials, non-wetted parts

Ʋ Probe - double rod fully insulated:

ø 14 mm (0.551 in)

316L

Ʋ Plastic housing

plastic PBT (Polyester)

Ʋ Aluminium die-casting housing

Aluminium die-casting AlSi10Mg, powder-coated - basis:

Polyester

Ʋ Stainless steel housing - precision

casting

316L

Ʋ Stainless steel housing, electropol-

ished

316L

Ʋ Seal between housing and housing

cover

NBR (stainless steel housing, precision casting), silicone

(aluminium/plastic housing; stainless steel housing,

electropolished)

Ʋ Ground terminal

316L

Process fittings

Ʋ Flanges

DIN from DN 50, ANSI from 2"

Weight

1)

Ʋ Instrument weight

0.8 … 4 kg (0.18 … 8.82 lbs)

Ʋ Rod weight: ø 14 mm (0.551 in)

2000 g/m (22 oz/ft)

Sensor length (L)

0.2 … 4 m (0.656 … 13.12 ft)

Max. lateral load

10 Nm (7.4 lbf ft)

Output variable
Output signal

4 … 20 mA/HART

HART output values

Ʋ HART value (Primary Value)

Capacitance

Ʋ HART value (Secondary Value)

Capacitance - scaled

Resolution

1.6 µA

Failure signal current output (adjustable) mA value unchanged 20.5 mA, 22 mA, < 3.6 mA (adjust-

able)

Current limitation

22 mA

Load

see load diagram under Power supply

Damping (63 % of the input variable)

0 … 999 s, adjustable

Rise time

500 ms (ti: 0 s, 0 … 100 %)

1)

Flange weight not considered