3 wiring plan – VEGA VEGABOX 02 User Manual

Page 12

Advertising
background image

1

Snap VEGABOX 02 onto the carrier rail or screw it to the mounting
plate

2

Loosen the cover screws and remove the cover

3

Insert the sensor cable into VEGABOX 02 through the cable entry

4

Loosen the screws with a screwdriver

5

Insert the wire ends into the open terminals according to the wiring
plan

6

Tighten the screws with a screwdriver

7

Check the hold of the wires in the terminals by lightly pulling on
them

8

Tighten the compression nut of the cable entry. The seal ring must
completely encircle the cable

9

Connect the supply cable according to steps 3 to 8

10 Screw the housing cover back on

The electrical connection is hence finished.

5

.3 Wiring plan

1

2

+

1

2

3

4

5

6

1

2

3

4

5

6

Fig. 3: Terminal assignment VEGABOX 02

1

To power supply or the processing system

2

Shielding

1

)

Wire number

Wire colour/Polarity

VEGABOX 02 terminal

1

brown (+)

1

2

blue (-)

2

1)

Connect screen to ground terminal. Connect ground terminal on the outside
of the housing as prescribed. The two terminals are galvanically connected.

VEGAWELL 52 -, 72 - 4 …
20

mA

12

VEGABOX

02

5 Connecting to power supply

32798

-EN

-120820