VEGA Connection cable IP 66_IP 68 (1 bar) User Manual
Page 6
Advertising
6
6
5
5
6
5
5
6
2
3
4
1
Fig. 2: Position of the cable gland and filter element with the different housing
versions
1
Stainless steel (electro-polished)
2
Stainless steel (precision casting)
3
Alu double chamber
4
Alu single chamber
5
Cable gland
6
Filter element
Proceed as follows for mounting:
1
Unscrew the existing cable gland
2
Screw in the cable gland of the IP 66/IP 68, 1 bar connection cable
3
Connect the wires according to chapter "Connect"
4
Unscrew the filter element (consisting of four parts)
5
Screw in the blind stopper
6
Lead the loose end of the connection cable into a suitable
connection box with pressure compensation, e.g. VEGABOX 02
6
Connection cable IP 66/IP 68 (1 bar) • Retrofit set/Accessory for plics sensors
3 Mounting
34107
-EN
-120524