3 separator with ex applications, 4 wiring plan, Connection on the passive input of the ea card – VEGA VEGALOG 571 EA User Manual

Page 13

Advertising
background image

5.3 Separator with Ex applications

In Ex applications, an additional separator must be used. The

following types can be used:

l

VEGATRENN 149A Ex

- requires additional supply voltage (20 … 253 V)

- particularly suitable for long cable lengths

-

Connection on the passive input of the EA card

l

KFD0-CS-Ex1.51P

- no additional supply voltage necessary (loop-powered)

- suitable for short cable lengths with low voltage loss

-

Connection on the active input of the EA card

Take note of the connection instructions in the respective

operating instructions manual.

5.4 Wiring plan

Input

+

+

+

-

-

+

+

-

+

+

-

+

+

-

+

+

-

+

+

-

+

+

-

+

+

-

+

+

-

+

+

-

4

6

5

2

3

9

8

10

1

7

2

3

4

1

L (+)
N (-)

2

6

12

20

24

22

10

16

18

30

28

32

d b

z

14

26

8

4

d b

z

+

-

d b

z

Fig. 3: VEGALOG 571 EA

1)

1

Voltage supply for VEGALOG 571 EA

2

Connection sensor 1 … 10

3

Detail, connection without sensor supply (passive input)

4

Detail, connection with sensor supply (active input)

1)

Broken lines = Connections on the EA card.

VEGALOG 571 EA - Input card analogue

13

Connecting to voltage supply

31948

-EN

-070307